SOVA.evar Details

Main Features

  • One-click vessel lumen identification
  • Automated determination of the center lumen line and various editing tools
  • Visualization of the perpendicular MPR slice along the center line
  • Direct length and aortic angle measurements as well as diameter and in-plane angle measurement
  • Suitable combination of 2D and 3D visualizations
  • Efficient and user-friendly operation
  • Integrated stent graft sheets of the manufacturers which are filled out interactively
  • Suitability for stationary and mobile Apple workstations

Visualization Options

  • Direct Volume Rendering (DVR)
  • Multiplanar Reformation (MPR)
  • Curvilinear Planar Reformation (CPR)
  • Straigthened CPR
  • Maximum Intensity Projection (MIP)
  • Thick Slice visualization

OsiriX-based modular EVAR software

The software SOVA.evar is certified for clinical use (class IIb medical device) and extends the medical image viewer OsiriX (in certified versions, e.g. the aycan workstation OsiriX PRO) by an autonomous dedicated tool for EVAR sizing and planning. The complete system operates on a consumer Apple Mac Computer, e.g. on a stationary iMac or an mobile MacBook Pro. SOVA.evar processes DICOM image data of CT angiographies loaded from the OsiriX database and is capable of writing DICOM data such as reporting sheets and visualizations back into the database and to the PACS.

Besides SOVA.evar, also a non-certified version of the OsiriX plugin is available. This plugin is provided by our partner SOVA Distribution for non-clinical use (e.g. for medical research or training).

Workflow

Organize your DICOM studies and series with OsiriX. Select the desired series and start SOVA.evar.
Vessel Identification: In SOVA.evar, select the vascular structures with a single mouse click. If needed, refine the results using a simple tool.
Lumen Centerlines: From the automatically generated lumen center lines, select two lines and, if needed, adjust them according to your measurement strategy.
Lumen Centerlines: For example, straighten a centerline section in order to plan the required length of the stent graft more accurately.
Measurement: Assess diameter, length and angle parameters and enter the results in the stentgraft form of your choice. Angles can be measured both along the centerline (e.g. for measuring the aortic neck angle) as well as on the basis of the MPR plane orthogonal to the centerline.

Our workflow supports any measurement strategy.

Document your steps using the screenshot function and save the results back to the OsiriX database and (depending on your configuration) to the PACS.

Free Trial Version Request a quote

Requirements of SOVA.evar

Hardware

  • Apple Mac Intel Computer
  • RAM: 4 GB RAM (8 GB or more recommended)
  • Graphics board: 256 MB VRAM (512 MB or more recommended), OpenGL 2.x compatible *
  • Display resolution: ≥ WXGA (1280×800), higher resolution recommended
  • Mouse with scroll function (Apple Mouse / Apple Mighty Mouse recommended)

*) In rare cases it may be that a graphics board does meet the abovementioned requirements and is still not fully compatible. Upon request, we will inform you whether your graphics board is fully compatible, or not.

Software

  • Mac OS X, starting from 10.7
  • CE-labelled OsiriX Version, e.g. aycan OsiriX PRO v2.x

For details see compatibility. For other versions, e.g. for non-clinical use, please contact us via info@sovamed.com.

Image Data

  • homogeneously contrasted CTA DICOM image data
  • Slice distance: 2 mm or less recommended
  • no Gantry angulation
  • maximum number of slices which can be loaded depends on graphics hardware

New in SOVA.evar 1.1

The following features have been improved or newly developed since SOVA.evar version 1.0:

  • easier to use, enhanced work flow
  • optimized vessel analysis that is easier to handle
  • improved automatic creation of centerlines
  • global and local editing tools of the centerlines for full control and processing of difficult cases
  • interactive measuring of diameters and angles on orthogonal MPR slices
  • interactive assessment of aortic angles
  • integration of numerous new stent graft forms
  • improved visualization quality